张向军, 贾晓东, 王敏, 赵丹丽, 郭盈. 工作场所空气中氮氧化物测定方法优化J. 职业卫生与应急救援, 2026, 44(3): 396-399. DOI: 10.16369/j.oher.issn.1007-1326.2026.260020
引用本文: 张向军, 贾晓东, 王敏, 赵丹丽, 郭盈. 工作场所空气中氮氧化物测定方法优化J. 职业卫生与应急救援, 2026, 44(3): 396-399. DOI: 10.16369/j.oher.issn.1007-1326.2026.260020
ZHANG Xiangjun, JIA Xiaodong, WANG Min, ZHAO Danli, GUO Ying. Optimization of determination method for nitrogen oxides in workplace airJ. Occupational Health and Emergency Rescue, 2026, 44(3): 396-399. DOI: 10.16369/j.oher.issn.1007-1326.2026.260020
Citation: ZHANG Xiangjun, JIA Xiaodong, WANG Min, ZHAO Danli, GUO Ying. Optimization of determination method for nitrogen oxides in workplace airJ. Occupational Health and Emergency Rescue, 2026, 44(3): 396-399. DOI: 10.16369/j.oher.issn.1007-1326.2026.260020

工作场所空气中氮氧化物测定方法优化

Optimization of determination method for nitrogen oxides in workplace air

  • 摘要:

    目的 针对国标GBZ/T 160.29—2004《工作场所空气有毒物质测定无机含氮化学物》中样品采集、样品保存和结果计算等环节存在的不足,提出优化改进措施,以提升方法的准确性和可操作性。

    方法 在采样环节更换氧化剂,改变采样连接方式;在样品保存环节,细化样品保存条件与期限;在结果计算环节,引入氧化系数,完善计算公式。

    结果 本方法将氧化剂由三氧化铬变更为酸性高锰酸钾溶液,其氧化效果与三氧化铬相当,且可通过颜色变化方便判断氧化剂是否失效;将采样管连接方式优化为串联方式,该方式采样效率≥ 95.4%,满足标准要求,同时简化了操作。样品在30℃避光保存,可保存2 d;在20℃避光保存,可保存3 d;在0~4℃避光保存,至少可保存7 d。引入一氧化氮氧化成二氧化氮过程的氧化系数0.68,并将其纳入计算公式。

    结论 上述优化手段提升了方法在样品采集、样品保存和结果计算环节的准确性和可操作性,为工作场所空气中氮氧化物标准的修订提供了可靠的技术方案。

     

/

返回文章
返回