Citation: FENG Yuchao, GAO Yuan, ZHAO Yuan, SU Yiwei, ZHANG Jinwei, LIU Yimin. Investigation on occupational hazards of sewage pumping stations in five districts of Guangzhou from 2017 to 2018J. Occupational Health and Emergency Rescue, 2020, 38(4): 397-400. DOI: 10.16369/j.oher.issn.1007-1326.2020.04.019

2017—2018年广州市5辖区污水泵站职业病危害调查

Investigation on occupational hazards of sewage pumping stations in five districts of Guangzhou from 2017 to 2018

  • 摘要:
    目的 探究广州市5个辖区污水泵站职业病危害因素和职工健康状况,为企业职业卫生管理、制定相关管理策略提供依据。
    方法 采用现场职业卫生调查和描述流行病学的方法,收集广州市污水泵站2017—2018年职业病危害因素检测结果和工人职业健康监护资料,分析污水泵站的职业卫生状况。
    结果 共调查泵站36个,包括低负荷泵站12个、中负荷泵站16个、高负荷泵站8个。2017—2018年各泵站氨、硫化氢检测浓度、湿球黑球温度指数均符合国家职业接触限值的要求;噪声定点检测超标率为3.94%,超标岗位主要集中在中、高负荷泵站的水泵巡检位,个体噪声检测结果均符合职业接触限值的要求。2018年工人职业健康检查开展率为77.78%,工人体检率为61.21%,体检结果异常率为75.36%;检出6人需复查听力,2人为接触氨作业职业禁忌证,异常检出率前3位的疾病或症状分别为高血压(21.13%),体重偏重(19.72%),咽炎、扁桃体肿大(15.49%)。
    结论 广州污水泵站职业病危害因素水平较低,但仍应提高警惕,做好防护措施;此外职工体检率较低,体检异常率较高,企业应进一步完善和落实职业卫生管理制度保护职工健康。

     

/