  • 摘要:
      目的  对国家标准粉尘中游离二氧化硅测定方法进行改进。
      方法  分别用国标法和改进法对高、中、低3个浓度的粉尘中游离二氧化硅质量分数进行测定,并对检验结果进行比较分析。
      结果  改进法通过全自动石墨消解仪进行控温和消解。首先将消解仪的温度预热至200℃,样品在保持248℃的过程中,用玻璃棒每间隔2 min左右搅拌1次,使样品能充分消解。当消解仪温度达到设定温度248℃后,在每列6个样品中选择不相邻的2个样品用水银温度计进行校正。消解完成后,待焦磷酸溶液冷却至100℃以下,缓慢地将冷却的焦磷酸溶液转移至150 mL左右煮沸的蒸馏水中,并用玻璃棒不断搅拌,避免胶状物的产生,排除实验干扰。改进法最多可以同时进行72个样品的消解。分别用国标法和改进法测定高、中、低3个浓度的粉尘样品,所得二氧化硅质量分数差异均无统计学意义(P > 0.05)。
      结论  改进法提高了检测效率及安全性,可以用来测定工作场所粉尘中游离二氧化硅。

     

/